| Silicone Potted X-Ray Tubes |

Oxford Instrument's series 1000 is a highly popular and proven side window x-ray tube. Currently in use for many industrial applications, the TF1000 series features an electron gun assembly packaged in a silicone formed material. This provides a limited amount of x-ray shielding, and should only be used in a suitable radiation shielded enclosure. The tube is to be operated in a positive anode mode with the filament grounded.
The standard exit window is either 3, 5 or 10 mil Be.
Applications
Options
Specifications
| Anode current | 0.20 to 1.5 mA |
| Anode (target) voltage | 10 to 35kV |
| Maximum power | 15 watts continuous |
| Filament voltage | Up to 3.0V @ 30kV/1.5mA |
| Filament current | Up to 1.5 amps |
| Stability | 0.2% over 4 hours |
| Focal
spot size (nominal)* |
0.67 mm* *per IEC336, JISZ47045, NEMA XR5 |
| Stability | 0.2% over 4 hours |
| Mounting flange | Many designs available |
| Cathode type | W filament |
| Dimensions | 102 mm length by 33 mm diameter |
| Weight | <1 lb (~ 200 grams) |
| Cooling method | Forced air |
Maximum temperature of silicone potting surface not to exceed 55 degrees Celsius
Warning: This tube produces x-rays through the glass as well as the output port and must only be used in a suitable radiation shielded enclosure or test chamber.
Information Request:
For further information
on any of our products, please contact us at Sales@OxfordXTG.COM
| |
Copyright
© 2003
Oxford Instruments plc, all rights reserved. |